Interviews

An Interview with Juan Carlos Parodi, MD

Famous Vascular Surgeon: Juan Carlos Parodi, MD

Articles

This article was written by Juan Parodi, MD, inventor of EVAR. It describes the process by which he became aware of the sequelae strongly associated with stiff aortic stent-grafts. It also describes early attempts to create a compliant aortic stent-graft.


Parodi, Juan MD. Non-compliant Endografts for TEVAR Have a Detrimental Effect on Systolic Blood Pressure and Cardiac Function. VEITHsymposium Bulletin. 2021 Sept.
ARTICLE PDF

“It is obvious that the longer the aorta that is covered by a semi-rigid endograft, the greater the undesirable consequences will be.” Juan C. Parodi

Kamenskiy, Alexey PhD; Aylward, Paul MD; Desyatova, Anastasia PhD; DeVries, Matthew MD; Wichman, Christopher PhD; MacTaggart, Jason MD. Endovascular Repair of Blunt Thoracic Aortic Trauma is Associated With Increased Left Ventricular Mass, Hypertension, and Off-target Aortic Remodeling. Annals of Surgery 274(6):p 1089-1098, December 2021. | DOI: 10.1097/SLA.0000000000003768
ARTICLE PDF

OBJECTIVE: Test the hypothesis that trauma TEVAR is associated with LV mass increase and adverse off-target aortic remodeling.

  

METHODS: Computed Tomography Angiography (CTA) scans of 20 trauma TEVAR patients (17 M/3 F) at baseline [age 34.9 18.5 (11.4–71.5) years] and 5.1 3.1 (1.1–12.3) years after repair were used to measure changes in LV mass, LV mass index, and diameters and lengths of the ascending thoracic aorta (ATA). Measurements were compared with similarly-aged control patients without aortic repair (21 M/21 F) evaluated at similar follow-ups.

 

RESULTS: LV mass and LV mass index of TEVAR patients increased from 138.5 39.6 g and 72.35 15.17 g/m2 to 173.5 50.1 g and 85.48 18.34 g/m2 at the rate of 10.03 12.79 g/yr and 6.25 10.28 g/m2/yr, whereas in control patients LV characteristics did not change. ATA diameters of TEVAR patients increased at a rate of 0.60 0.80 mm/yr, which was 2.4-fold faster than in controls. ATA length in both TEVAR and control patients increased at 0.58 mm/yr. Half of TEVAR patients had hypertension at follow-up compared to only 5% at baseline.

  

CONCLUSIONS: TEVAR is associated with LV mass increase, development of hypertension, and accelerated expansile remodeling of the ascending aorta. Although younger trauma patients may adapt to these effects, these changes may be even more important in older patients with other aortic pathologies and diminished baseline cardiac function.

Kreibich M, Morlock J, Beyersdorf F, Berger T, Allweier S, Kondov S et al. Decreased Biventricular Function Following Thoracic Endovascular Aortic Repair. Interact CardioVasc Thorac Surg 2020;30:600–4.
ARTICLE PDF

OBJECTIVES: Preclinical studies have suggested acute stiffening of the aorta following experimental thoracic endovascular aortic repair (TEVAR), resulting in acute elevated pulse pressure, hypertension and possibly heart failure. The aim of this study was to evaluate cardiac remodelling following TEVAR.


METHODS: From 2005 to 2018, 519 TEVAR procedures were performed at a single centre. Transthoracic echocardiography was performed pre- and post-TEVAR in 31 patients without previous replacement of the thoracic aorta. Patient characteristics, drug information, radiographic and follow-up data were evaluated. Aortic details were measured in multiplanar reconstruction.


RESULTS: Transthoracic echocardiography was performed 2 ± 2 years after TEVAR. At this time, patients received significantly more antihypertensive drugs compared to the pre-TEVAR intake (beta-blocker therapy: P = 0.037; calcium channel blocker: P = 0.022). Compared to pre-TEVAR, there was a significant reduction in the left ventricular ejection fraction (P = 0.008) and tricuspid annular plane systolic excursion (P = 0.013) post-TEVAR. A significant increase in the left ventricular mass was not detected in this study (P = 0.95). The mean distance of 163 ± 66mm of the descending aorta was covered.


CONCLUSIONS:
This study suggests negative cardiac remodelling with a decrease in the left and right ventricular function following TEVAR despite an increase in oral antihypertensive medication. The impact of stiffer endovascular grafts compared with the native aortic wall should be considered by endovascular specialists and manufacturers.

Theodorus M J van Bakel, Christopher J Arthurs, Foeke J H Nauta, Kim A Eagle, Joost A van Herwaarden, Frans L Moll, Santi Trimarchi, Himanshu J Patel, C Alberto Figueroa, Cardiac remodelling following thoracic endovascular aortic repair for descending aortic aneurysms. European Journal of Cardio-Thoracic Surgery, Volume 55, Issue 6, June 2019, Pages 1061- 1070, https://doi.org/10.1093/ejcts/ezy399
ARTICLE PDF

OBJECTIVES: Current endografts for thoracic endovascular aortic repair (TEVAR) are much stiffer than the aorta and have been shown to induce acute stiffening. In this study, we aimed to estimate the impact of TEVAR on left ventricular (LV) stroke work (SW) and mass using a non-invasive image-based workflow.

 

METHODS: The University of Michigan database was searched for patients treated with TEVAR for descending aortic pathologies (2013–2016). Patients with available pre-TEVAR and post-TEVAR computed tomography angiography and echocardiography data were selected. LV SW was estimated via patient-specific fluid–structure interaction analyses. LV remodelling was quantified through morphological measurements using echocardiography and electrocardiographic-gated computed tomography angiography data.


RESULTS:
Eight subjects were included in this study, the mean age of the patients was 68 (73, 25) years, and 6 patients were women. All patients were prescribed antihypertensive drugs following TEVAR. The fluid–structure interaction simulations computed a 26% increase in LV SW post-TEVAR [0.94 (0.89, 0.34) J to 1.18 (1.11, 0.65) J, P = 0.012]. Morphological measurements revealed an increase in the LV mass index post-TEVAR of +26% in echocardiography [72 (73, 17) g/m2 to 91 (87, 26) g/m2, P = 0.017] and +15% in computed tomography angiography [52 (46, 29) g/m2 to 60 (57, 22) g/m2, P = 0.043]. The post- to pre-TEVAR LV mass index ratio was positively correlated with the post- to pre-TEVAR ratios of SW and the mean blood pressure (q = 0.690, P = 0.058 and q = 0.786, P = 0.021, respectively).

 

CONCLUSIONS: TEVAR was associated with increased LV SW and mass during follow-up. Medical device manufacturers should develop more compliant devices to reduce the stiffness mismatch with the aorta. Additionally, intensive antihypertensive management is needed to control blood pressure post-TEVAR.

Hiraoka A, Toki M, Hayashida A, Chikazawa G, Yoshida K, Sakaguchi T et al. Exercise Stress Echocardiogram for the Evaluation of Change in the Ventricular–arterial Interaction after Thoracic Endovascular Aortic Repair. Eur J Cardiothorac Surg 2018; doi:10.1093/ejcts/ezy342.
ARTICLE PDF

OBJECTIVES: The aim of this study was to explore, with exercise echocardiography, the potential impact of thoracic endovascular aortic repair (TEVAR) on the ventricle–aorta coupling, based on the hypothesis that the interaction between the ventricle and aorta may be influenced by an increase in aortic stiffness due to the stent graft.


METHODS: Of the patients who underwent isolated TEVAR for thoracic aortic diseases between April 2016 and December 2016, changes found in haemodynamic and echocardiographic parameters between the control (n = 17) and TEVAR (n = 30) groups were analysed by a stress echocardiogram.


RESULTS: The end-systolic elastance significantly increased with stress in both groups [from 3.0 (2.5–4.5) mmHg/ml to 4.8 (3.7–6.5) mmHg/ml, P < 0.001, in the control group and from 2.9 (2.0–3.5) mmHg/ml to 3.4 (2.6–4.2) mmHg/ml, P < 0.001, in the TEVAR group]. The arterial elastance significantly elevated only in the TEVAR group [from 1.6 (1.3–1.8) mmHg/ml to 1.7 (1.5–2.0) mmHg/ml, P = 0.007] and arterial elastance/end-systolic elastance (ventricular–arterial coupling) significantly decreased only in the control group [from 0.5 (0.4–0.7) to 0.4 (0.3–0.5), P = 0.002, in the control group and from 0.6 (0.4–0.8) to 0.5 (0.4–0.6), P = 0.10, in the TEVAR group]. In the control group, the change in end-systolic elastance and ventricular–arterial coupling tended to be greater (P = 0.002 and 0.07).


CONCLUSIONS: An exercise echocardiogram showed the underlying influences of TEVAR on the interaction between the heart and aorta. TEVAR may have the potential to suppress left ventricular contractile capacity and increase cardiac afterload during exercise

Spadaccio C, Rainer A, Barbato R, Chello M, Meyns B. The Fate of Large-diameter Dacron® Vascular Grafts in Surgical Practice: Are We Really Satisfied? Int J Cardiol. 2013 Oct 12;168(5):5028-9. doi: 10.1016/j.ijcard.2013.07.165. Epub 2013 Jul 25. PMID: 23932043.
ARTICLE PDF

… what really emerged from the analysis of the long-term surgical experience with Dacron® grafts is the increasing evidence that the mismatch in biomechanical properties between prosthetic material and native aorta is at the root of daunting issues in the long-term followup of these patients.